IMS – LANTIME M1000S
Compact Modular Synchronisation Solution - 1U ETSI Rackmount
Versatile and Modular Solution for Time and Frequency Synchronisation Applications in 1U housing
The compact 1RU form factor, the hot plugging and hot swapping capabilities and the large selection of different modules for input/output sync signals, network Synchronisation interfaces and clock modules with different GNSS/radio receiver and oscillator options offer an unmatched reliability, scalability and flexibility. As every Intelligent Modular Synchronisation (IMS) system, the M1000S can play almost any role in your Synchronisation infrastructure: Edge Grandmaster Clock, PRC, PRTC, Secure Sync Gateway, Protocol/Sync Signal Translator and many more.
The 1U chassis has two power supply slots, optional two clock module slots, a CPU slot and four (three in case of a second reference clock) slots for additional input and output modules. Adding a second clock module and a second power supply transforms the IMS – M1000S into a fully redundant solution. Both, wide range AC and a 20-60 V DC power supply model can be mixed and matched as required.
The IMS LANTIME S models are an alternative for application environments where a display with function keys is not required for onsite configuration. This allows the S housing variants to be installed in racks which are only accessible from one side.
Key Features
- Optimized space usage
- Synchronisation of NTP and SNTP compatible clients
- Web-based status and configuration interface and console-based graphical configuration utility
- IMS - Intelligent Modular System platform
- Up to 4 PTP (IEEE 1588-2008) modules
- Redundant power and receiver option (eg GPS / GLONASS combination)
- Hot Plug
- Arbitrary combinations of modules
- Meinberg's LANTIME time server is available with a variety of additional output options: IRIG Time Code, frequency synthesizer and programmable pulse outputs illustrate some of the many expansion options for your NTP server
- Up to 16 additional LAN ports
Need help selecting the right solution?
Our technical specialists can help you choose the right product, answer technical questions and provide a quotation.
Technical Specifications
| Operating Temperature | 0 ... 50°C / 32 ... 122°F |
|---|---|
| RoHS | Yes |
| CPU |
|
| Accuracy of Pulse Outputs | < ±50ns (OCXO SQ, OCXO MQ, OCXO HQ, OCXO DHQ) |
| Control Elements | value goes here |
| Daytime Protocol (DAYTIME) | Daytime Protocol (RFC 867) |
| Firmware Updates | Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection. Software updates are provided free of charge, for the lifetime of your Meinberg product. |
| Frequency Outputs | Accuracy depends on oscillator (standard: OCXO-SQ) |
| Further Information | As a cost effective alternative to the LANTIME M1000 standard model, the M1000S has all connectors and control elements on its front panel, allowing to mount it inside racks that are only accessible from one side.
NTP Time Server for large Networks With up to 25,000 NTP requests per second, the system is able to provide time for hundreds and thousands of NTP clients. The LANTIME module supports the following protocols: IPv4, IPv6, NTP / SNTP (v2, v3, v4), PRP (IEC 62439-3), HTTP (S), SSH, Telnet, SNMP (v1, v2, v3), FTP, SFTP, DHCP/DHCPv6. For each system, up to 99 logical network interfaces are available (99 IPv4 and 99 IPv6 addresses). Scalable NTP Time Server System All modules are hot-plug capable and the modules can be configured via the central web interface (from the CPU module). Almost infinite number of combinations of input and output modules are available to meet almost any Synchronisation task. Because of simple extension by upgrading the system with new modules the scalability of the M1000S system is ensured. Slots for Input Signals: IMS-MRI: Standard reference inputs IMS-ESI: Extended reference inputs Both of these reference input interfaces may also be used as I/O slot. The Active Cooling Module allows the installation of the M1000S safely within the temperature specification. The ACM is easily field-replaceable and allows for a hot-plug replacement without the need to power down the unit. |
| Hypertext Transfer Protocol (HTTP) | HTTP/HTTPS (RC 2616) |
| IEC 61850 | Synchronisation of IEC 61850 compliant devices by using SNTP |
| Internet Protocol (IP) | IP v4, IP v6 |
| Network Interface |
|
| Network Autoconfiguration Support |
|
| Network Interface |
|
| Network Protocols OSI Layer 4 Transport Layer | TCP, UDP |
| Network Protocols OSI Layer 7 Application Layer | TELNET, FTP, SSH (incl. SFTP, SCP), HTTP, HTTPS, SYSLOG, SNMP |
| Network Time Protocol (NTP) |
|
| Operating System of the SBC | GNU/Linux 4.x |
| Parallel Redundancy Protocol (PRP) | PRP (IEC 62439-3) |
| Power Supply Maximum Power Range |
|
| Reference Options |
|
| Relative Humidity | Max. 85% |
| Scope of Supply | The scope of delivery includes a CAB-CONSOLE-RJ45 cable for initial start of operation, documentation and software on USB stick. |
| Secure Shell SSH | SSH v1.3, SSH v1.5, SSH v2 (OpenSSH) |
| Simple Network Management Protocol (SNMP) | SNMPv1 (RFC 1157), SNMPv2c (RFC 1901-1908), SNMP v3 (RFC 3411-3418) |
| Technical Support | Meinberg offers free lifetime technical support via telephone or e-mail. |
| Telnet | Telnet (RFC 854-RFC 861) |
| Time Protocol (TIME) | Time Protocol (RFC 868) |
| WEEE Status of the Product | B2B. Return to manufacturer |
Downloads
| Datasheet | Click to view Datasheet (PDF) |
|---|---|
| Manual | Click to view Manual (PDF) |